Architect - Consultant Resume
4.00/5 (Submit Your Rating)
Brooklyn, NY
PROFESSIONAL EXPERIENCE:
Confidential, Brooklyn, NY
Architect - Consultant
- Responsible for engineering all aspects of SCCM CB (1610) supporting 25k
- Design and implementation of SCCM 1610 supporting 25k clients in 70 locations across New York City
- Engineered process to identify machines in Active Directory not being managed by SCCM to ensure complete client coverage
- Creation of multiple custom SSRS reports in regards to software update compliance status as well as client health
- Engineered RBAC for SCCM CB (1610) allowing specific site locations control only to their specific assets
- Setup of SCCM CB lab to mimic production for use in baseline and testing of cloud management gateway on Azure
- Engineered process to support machines in separate forest for customer facing kiosk machines to ensure isolation from production infrastructure.
- Tier 3 support for SCCM infrastructure
- Setup SQL replica for use in reporting for Service Now
- Responsible for all documentation for SCCM CB (1610) global installation process
Confidential, Bridgewater, NJ
Architect - Consultant
- Responsible for engineering all aspects of SCCM CB (1606) supporting 160k clients
- Engineering upgrade of SCCM 2012 R2 to SCCM CB (1606)
- Deployed SCCM CB (1606) to production.
- Setup MDT 2013 Update 2 with SCCM CB (1606) integration
- Engineered SCCM CB (1606) client install process via GP0, greatly increasing install success rate
- Engineered process with network team allowing isolated clients to communicate with SCCM infrastructure using reverse proxy
- Engineered process allowing machines to be “tagged” via AD attribute ensuring isolation of critical machines from standard machines. These machines were managed by another team with “white glove” support.
- Engineered SCCM CB (1606) infrastructure across multiple forests including DMZ
- Responsible for all documentation for SCCM CB (1606) global installation process
- Engineered disaster recovery process for SCCM CB (1606)
- Engineered RBAC for SCCM CB (1606) allowing multiple LOB’s control only over their specific assets
- Performed extensive base lining of server hardware in regards to performance (ex: MIF / Status / State message processing rates)
- SQL Administration / troubleshooting
- Tier 3 support for SCCM infrastructure
- Troubleshooting of SCCM CB (1606) application model installs on client machines
- Troubleshooting of SCCM CB (1606) Software update deployments on client machines
Confidential, Bridgewater, CT
Architect - Consultant
- Responsible for engineering all aspects of SCCM 2012 R2 supporting 20k clients
- Engineered migration off of legacy LANDesk infrastructure to SCCM 2012 R2
- Setup of compliance settings for CM2012 used for auto remediation of server baselines
- Setup MDT 2013 infrastructure with SCCM 2012 integration
- Responsible for all documentation for SCCM 2012 global installation process
- Engineered disaster recovery process for SCCM 2012
- Engineer and documentation of SCCM 2012 PXE point installations
- Virtualized all SCCM servers
- Designed SQL queries for use by the application deployment team to track application deployments
- Troubleshooting of SCCM 2012 application model installs on client machines
- Troubleshooting of SCCM 2012 Software update deployments on client machines
- Engineering of SCUP 2011 for use with 3rd party patching process
Confidential, Jersey City, New Jersey
Lead Architect - Vice President
- Responsible for engineering all aspects of SCCM 2012 R2 supporting 255k client globally
- Designed global SCCM 2012 R2 infrastructure consisting of 5 primaries, 180 remote distribution points and 20 secondary sites
- Merged 2 separate 2007 infrastructures, one supporting servers and one supporting workstations into one SCCM 2012 infrastructure
- Designed process for auto patching of all servers using maintenance windows based off hardware inventory captures of WMI classes
- Setup MDT 2010 and MDT 2012 infrastructure with SCCM2007 and Configuration Manager 2012 integration
- Team lead of engineering group consisting of 10 engineers
- Engineered SQL Server Reporting Services implementation
- In depth troubleshooting of SQL and SCCM performance issues using SQL profiler and SQL tracing in SCCM 2012.
- Setup of multiple SUP points for redundancy with SCCM patching using both SQL 2012 and Windows Internal Database
Confidential, Iselin, New Jersey
Premier Field Engineer
- Provide customer support / engineering at customer sites
- Worked directly with Confidential customers on all aspects of SCCM 2007 and Configuration Manager 2012
- Certified trainer for Configuration Manager 2012 product
- Design review of Configuration Manager 2012 for large financial customer with over 400k clients
- Worked with Configuration Manager 2012 product team to resolve product / bug issues
- Design and setup of production Configuration Manager 2012 environment
- Documentation of SCCM 2007 to SCCM 2012 migration plan
- Setup of compliance settings for SCCM 2012
- Troubleshooting / tier 3 level support
- Setup of OSD / Task sequences at customer sites
- Setup of remote SQL 2008 for use with Configuration Manager 2012
Confidential, Bridgewater, New Jersey
Lead Engineer - Consultant
- Responsible for engineering all aspects of SCCM 2007 R3 supporting 120k client globally
- Designed 3 tier global SCCM 2007 infrastructure consisting of 10 primaries and 125 secondary sites
- Engineered upgrade process from SMS 2003 SP3 to SCCM 2007 R3 infrastructure
- Designed SCCM SUM patching process for SCCM 2007
- Engineered SQL 2008 Standard / Enterprise silent install for use by Operations team
- Engineered process to increase C: drive partition on production SCCM servers using Gpart utility, allowing critical SCCM servers to remain in production without having to be rebuilt
- Engineered / installation of SQL 2008 replica using log shipping process for Tier 1 SCCM database, enabling outside consumers the ability to pull data without impacting performance of Tier 1 SCCM database
- Creation of all engineering documentation for hand off to operations group
- Integration of acquired businesses into SCCM 2007 infrastructure
Confidential, Jersey City, New Jersey
Lead Engineer - Vice President
- Responsible for engineering all aspects of SCCM 2007 R2/SP2 supporting 182k client globally
- Designed 4 tier global SCCM 2007 infrastructure consisting of 40 primaries and 155 secondary sites
- Designed SCCM SUM patching process SCCM 2007
- Designed DCM process for faster reporting on registry, WMI, etc.
- Performed extensive baselining of server hardware in regards to performance (ex: MIF / Status / State message processing rates)
- Virtualized 30% of SCCM secondaries with end state of all secondaries being virtualized
- Team lead of engineering group consisting of 8 engineers
- Engineered 1E product line (Nomad, Wakeup, Nightwatchman) for global production
Confidential, New York, New York
Lead Engineer
- Responsible for engineering of backend infrastructure systems supporting 22k clients globally.
- Team lead / mentoring of group consisting of 12 engineers
- Project to collapse 18 domains and 4 forests into 1 forest / 1 domain globally
- Design, rollout and support of Metraframe XP farm, consisting of 70 servers running on HP Proliant blade servers globally
- Patching 22k desktops / servers using SMS 2.0 SUS / SMS 2003 SUS
Confidential, New York, New York
Senior Technologist
- Responsible for all aspects of technology for Internet startup focusing on wireless web application development
- Build and configuration of Windows 2000 servers
- Install of Windows 2000 network, including DNS, DHCP, WINS, and Active Directory
- Support of XP and W2k client systems
- Installation and administration of SQL 7.0
- Configuration and installation of various routers and switches
- Responsible for Kixtart scripts and other scripting programs used by technicians